Update.windowsdefenderhost.com related threats. GitHub Gist: instantly share code, notes, and snippets.
Printable version
* RECOMMENDED * HP Lights-Out Configuration Utility
By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.
Type:
Software - Lights-Out Management
Version:
4.01(10 Sep 2012)
Operating System(s):
Microsoft Windows 7 (64-bit)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Vista (32-bit)
Microsoft Windows XP Professional
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
Microsoft Windows 7 (32-bit)
File name:
SP58155.exe (603 KB)
The Lights-Out Configuration Utility (CPQLOCFG.EXE) is a Windows®-based utility that connects to iLO 2, iLO 3 or iLO 4 using a secure connection over the network. RIBCL scripts are passed over the secure connection to CPQLOCFG. This utility requires a valid user ID and password with the appropriate privileges.
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Prerequisites:
This utility requires the following minimum firmware revisions:
Integrated Lights-Out 4 firmware version 1.00 or later
To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:
SP58155.exe
a88a0cd2680b593b366005c3fc442b62
Reboot Requirement: Reboot is not required after installation for updates to take effect and hardware stability to be maintained.
Installation: Create a directory on your hard-drive.
Copy this SoftPaq to the new directory.
From this new directory, run SoftPaq to extract the necessary files.
See the RIBCL scripting guidelines in the iLO User Guide.
Sample scripts for cpqlocfg may be downloaded from www.hp.com/go/ilo. Select your Lights-Out product, click on 'Download software' link, select the operating system. Download 'HP Lights-Out XML Scripting Sample for Windows' or 'HP Lights-Out XML PERL Scripting Sample for Linux'.
End User License Agreements: Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Availability:
Important Notes: None
Deliverable Name: HP Lights-Out Configuration Utility
Release Version and/or Date: 4.01
Last Recommended or Critical Version: 4.01
Previous Version of Firmware: 4.00
Upgrade Requirements: Optional: Users should update to this firmware version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Firmware Dependency: This software works best with the following firmware revisions:
Integrated Lights-Out 4 firmware (any version)
Enhancements/New Features:
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Problems Fixed:
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Known Issues:
None
Notes: Documentation Instructions for using this utility and RIBCL syntax for iLO can be found in the HP Integrated Lights-Out Management Processor Scripting and Command Line Resource Guide available at following the link at: http://www.compaq.com/products/servers/management/ilo/documentation.html
Sample XML scripts may be downloaded from www.hp.com/go/ilo. Select your Lights-Out product, click on 'Download software' link, select the operating system. Download 'HP Lights-Out XML Scripting Sample for Windows' or 'HP Lights-Out XML PERL Scripting Sample for Linux'.
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Important Notes: None
Deliverable Name: HP Lights-Out Configuration Utility
Release Version and/or Date: 4.01
Last Recommended or Critical Version: 4.01
Previous Version of Firmware: 4.00
Upgrade Requirements: Optional: Users should update to this firmware version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Firmware Dependency: This software works best with the following firmware revisions:
Integrated Lights-Out 4 firmware (any version)
Enhancements/New Features:
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Problems Fixed:
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Known Issues:
None
Version:4.23 (25 May 2018)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Resolved an issue where unexpected error encountered while reading iLO response.
CPQLOCFG is now signed by Hewlett Packard Enterprise.
Version:4.22 (6 Oct 2017)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Support for Integrated Lights-Out 2 firmware version 2.30 when AES encryption is enabled.
Version:4.21 (4 Apr 2015)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Fixed an issue where CPQLOCFG will not work as expected when SSL certificate of size greater than 2048 bytes is imported using IMPORT_CERTIFICATE tag.
Version:4.20 (30 Jan 2015)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Added support for iLO2 Firmware v2.27 (To address the “POODLE” security vulnerability, the iLO security policy has changed. SSLv3 is now disabled and TLSv1 is enabled in iLO2 v2.27.)
None
Version:4.1 (19 Feb 2013)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
The CPQLOCFG Utility might stop functioning while executing the cpqlocfg.exe -s command.
Added support for IPv6 Network Configuration on iLO 4 based servers.
Version:4.01 (10 Sep 2012)
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Version:4.00 (16 Apr 2012)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Optional upgradation for iLO 4 support.
Added support for iLO 4.
Version:3.5 (26 Oct 2012)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Added support for IPv6 Network Configuration on iLO 3 based servers.
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Version:3.2 (13 Jun 2011)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support to configure Kerberos-based authentication for iLO 3.
Version:3.1 (29 Nov 2010)
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
This verson is recommended for users running common scripts for iLO2 and iLO3.
Changed the logic to ignore and continue execution when iLO reports 'Feature Not Supported' RIBCL status.
Version:3 (26 Apr 2010)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for Integrated Lights-Out 3 (iLO 3).
Version:2.27 (10 Dec 2008)
Added support for IMPORT_SSH_KEY RIBCL command.
Added the variable substitution feature for CPQLOCFG 2.27.
Version:2.26 (5 May 2008)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
In Verbose mode, the keystrokes that a user inputs for the password will no longer be echoed to the screen.
Upon CPQLOCFG connection to the server, the negotiated cipher strength will be displayed.
Version:2.25 (11 Nov 2005)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for firmware upgrade image sizes larger than 2MB. This version is required to upgrade iLO 2 version 1.00 and later. Version:2.24 (14 Jul 2005)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for the certificate management commands present in iLO firmware 1.80 and later. Version:2.23(A) (17 Nov 2004)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for the certificate management commands present in iLO firmware 1.64 and later. Version:2.22(A) (2 Mar 2004)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Updated to allow entering login name and password from the command line. Version:2.21(A) (6 Jan 2004)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Updated to allow properly formatted XML responses to be returned from the client. Version:2.20(A) (10 Jun 2003)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Supports multi-packet response from firmware. Version:2.10(A) (10 Oct 2002)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Updated the following:
Enhanced error reporting.
Allow user to specify SSL port number; default :443.
Version:2.00(A) (9 Aug 2002)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Initial release.
Type:
Software - Lights-Out Management
Version:
4.01(10 Sep 2012)
Operating System(s):
Microsoft Windows 7 (32-bit)
Microsoft Windows 7 (64-bit)
Microsoft Windows Server 2008 R2
Microsoft Windows Server 2008 W32
Microsoft Windows Server 2008 x64
Microsoft Windows Vista (32-bit)
Microsoft Windows XP Professional
Red Hat Enterprise Linux 5 Server (x86)
Red Hat Enterprise Linux 5 Server (x86-64)
Red Hat Enterprise Linux 6 Server (x86)
Red Hat Enterprise Linux 6 Server (x86-64)
SUSE Linux Enterprise Server 10 (AMD64/EM64T)
SUSE Linux Enterprise Server 10 (x86)
SUSE Linux Enterprise Server 11 (AMD64/EM64T)
SUSE Linux Enterprise Server 11 (x86)
Description
The Lights-Out Configuration Utility (CPQLOCFG.EXE) is a Windows®-based utility that connects to iLO 2, iLO 3 or iLO 4 using a secure connection over the network. RIBCL scripts are passed over the secure connection to CPQLOCFG. This utility requires a valid user ID and password with the appropriate privileges.
Enhancements
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Installation Instructions
Prerequisites:
This utility requires the following minimum firmware revisions:
Integrated Lights-Out 4 firmware version 1.00 or later
To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:
SP58155.exe
a88a0cd2680b593b366005c3fc442b62
Reboot Requirement: Reboot is not required after installation for updates to take effect and hardware stability to be maintained.
Installation: Create a directory on your hard-drive.
Copy this SoftPaq to the new directory.
From this new directory, run SoftPaq to extract the necessary files.
See the RIBCL scripting guidelines in the iLO User Guide.
Sample scripts for cpqlocfg may be downloaded from www.hp.com/go/ilo. Select your Lights-Out product, click on 'Download software' link, select the operating system. Download 'HP Lights-Out XML Scripting Sample for Windows' or 'HP Lights-Out XML PERL Scripting Sample for Linux'.
Release Notes
End User License Agreements: Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Availability:
Important Notes: None
Deliverable Name: HP Lights-Out Configuration Utility
Release Version and/or Date: 4.01
Last Recommended or Critical Version: 4.01
Previous Version of Firmware: 4.00
Upgrade Requirements: Optional: Users should update to this firmware version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Firmware Dependency: This software works best with the following firmware revisions:
Integrated Lights-Out 4 firmware (any version)
Enhancements/New Features:
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Problems Fixed:
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Known Issues:
None
Notes: Documentation Instructions for using this utility and RIBCL syntax for iLO can be found in the HP Integrated Lights-Out Management Processor Scripting and Command Line Resource Guide available at following the link at: http://www.compaq.com/products/servers/management/ilo/documentation.html
Sample XML scripts may be downloaded from www.hp.com/go/ilo. Select your Lights-Out product, click on 'Download software' link, select the operating system. Download 'HP Lights-Out XML Scripting Sample for Windows' or 'HP Lights-Out XML PERL Scripting Sample for Linux'.
Fixes
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Availability
Important Notes: None
Deliverable Name: HP Lights-Out Configuration Utility
Release Version and/or Date: 4.01
Last Recommended or Critical Version: 4.01
Previous Version of Firmware: 4.00
Upgrade Requirements: Optional: Users should update to this firmware version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Firmware Dependency: This software works best with the following firmware revisions:
Integrated Lights-Out 4 firmware (any version)
Enhancements/New Features:
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Problems Fixed:
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Known Issues:
None
Revision History
Version:4.23 (25 May 2018)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Resolved an issue where unexpected error encountered while reading iLO response.
CPQLOCFG is now signed by Hewlett Packard Enterprise.
Version:4.22 (6 Oct 2017)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Support for Integrated Lights-Out 2 firmware version 2.30 when AES encryption is enabled.
Version:4.21 (4 Apr 2015)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Fixed an issue where CPQLOCFG will not work as expected when SSL certificate of size greater than 2048 bytes is imported using IMPORT_CERTIFICATE tag.
Version:4.20 (30 Jan 2015)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Added support for iLO2 Firmware v2.27 (To address the “POODLE” security vulnerability, the iLO security policy has changed. SSLv3 is now disabled and TLSv1 is enabled in iLO2 v2.27.)
None
Version:4.1 (19 Feb 2013)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
The CPQLOCFG Utility might stop functioning while executing the cpqlocfg.exe -s command.
Added support for IPv6 Network Configuration on iLO 4 based servers.
Version:4.01 (10 Sep 2012)
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Version:4.00 (16 Apr 2012)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Optional upgradation for iLO 4 support.
Added support for iLO 4.
Version:3.5 (26 Oct 2012)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
CPQLOCFG Utility may crash while executing cpqlocfg.exe -s command.
CPQLOCFG may return an error 'Invalid Address' with error code 10022 if Fully Qualified Domain Name is used instead of IP address.
Script Failed error may display when the '-t' syntax is used for XML substitution.
CPQLOCFG utility may stop working while executing Update_Firmware.xml if the Firmware Image location in the script is wrong.
Executing some scripts may give 'Script Succeeded' message instead of the Parse error for invalid entry.
Added support for IPv6 Network Configuration on iLO 3 based servers.
Added CDATA tag use. Users should be able to set Security Message for login banner using CPQLOCFG with the script Set_Security_Msg.xml now.
Version:3.2 (13 Jun 2011)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support to configure Kerberos-based authentication for iLO 3.
Version:3.1 (29 Nov 2010)
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
This verson is recommended for users running common scripts for iLO2 and iLO3.
Changed the logic to ignore and continue execution when iLO reports 'Feature Not Supported' RIBCL status.
Version:3 (26 Apr 2010)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for Integrated Lights-Out 3 (iLO 3).
Version:2.27 (10 Dec 2008)
Added support for IMPORT_SSH_KEY RIBCL command.
Added the variable substitution feature for CPQLOCFG 2.27.
Version:2.26 (5 May 2008)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
In Verbose mode, the keystrokes that a user inputs for the password will no longer be echoed to the screen.
Upon CPQLOCFG connection to the server, the negotiated cipher strength will be displayed.
Version:2.25 (11 Nov 2005)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for firmware upgrade image sizes larger than 2MB. This version is required to upgrade iLO 2 version 1.00 and later. Version:2.24 (14 Jul 2005)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for the certificate management commands present in iLO firmware 1.80 and later. Version:2.23(A) (17 Nov 2004)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Added support for the certificate management commands present in iLO firmware 1.64 and later. Version:2.22(A) (2 Mar 2004)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Updated to allow entering login name and password from the command line. Version:2.21(A) (6 Jan 2004)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Updated to allow properly formatted XML responses to be returned from the client. Version:2.20(A) (10 Jun 2003)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Supports multi-packet response from firmware. Version:2.10(A) (10 Oct 2002)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Updated the following:
Enhanced error reporting.
Allow user to specify SSL port number; default :443.
Version:2.00(A) (9 Aug 2002)
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Initial release.
Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.